Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Biochem Med (Zagreb) ; 34(1): 010502, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38125621

RESUMO

YKL-40 or Chitinase-3-Like Protein 1 (CHI3L1) is a highly conserved glycoprotein that binds heparin and chitin in a non-enzymatic manner. It is a member of the chitinase protein family 18, subfamily A, and unlike true chitinases, YKL-40 is a chitinase-like protein without enzymatic activity for chitin. Although its accurate function is yet unknown, the pattern of its expression in the normal and disease states suggests its possible engagement in apoptosis, inflammation and remodeling or degradation of the extracellular matrix. During an inflammatory response, YKL-40 is involved in a complicated interaction between host and bacteria, both promoting and attenuating immune response and potentially being served as an autoantigen in a vicious circle of autoimmunity. Based on its pathophysiology and mechanism of action, the aim of this review was to summarize research on the growing role of YKL-40 as a persuasive biomarker for inflammatory diseases' early diagnosis, prediction and follow-up (e.g., cardiovascular, gastrointestinal, endocrinological, immunological, musculoskeletal, neurological, respiratory, urinary, infectious) with detailed structural and functional background of YKL-40.


Assuntos
Biomarcadores , Proteína 1 Semelhante à Quitinase-3 , Doença , Inflamação , Proteína 1 Semelhante à Quitinase-3/metabolismo , Inflamação/enzimologia , Inflamação/genética , Biomarcadores/sangue , Biomarcadores/metabolismo , Doença/genética , Pesquisa/tendências , Humanos , Animais , Diagnóstico Precoce
2.
Lab Med ; 2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37294928

RESUMO

OBJECTIVE: To investigate the association of immune response with vaccination adverse effects at peak anti-receptor-binding domain spike subunit 1 (anti-RBDS1) IgG after full vaccination with Comirnaty, Spikevax, or Vaxzevria. METHODS: Anti-RBDS1 IgG concentrations after vaccination were determined in healthy adults vaccinated with the Comirnaty, Spikevax, and Vaxzevria vaccines. The association of reactogenicity and peak antibody response after vaccination was tested. RESULTS: Anti-RBDS1 IgG values were significantly higher in the Comirnaty and Spikevax group, compared with the Vaxzevria group (P < .001). Fever and muscle pain were found to be significant independent predictors of peak anti-RBDS1 IgG in the Comirnaty and Spikevax groups (P = .03 and P = .02, respectively). The multivariate model, adjusted for covariates, showed that no association between reactogenicity and peak antibody concentrations was found in the Comirnaty, Spikevax, and Vaxzevria groups. CONCLUSIONS: No association between reactogenicity and peak anti-RBDS1 IgG after vaccination with the Comirnaty, Spikevax, and Vaxzevria vaccine was found.

4.
Front Pediatr ; 10: 768260, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35359908

RESUMO

Background: Febrile illnesses in young children can be a major diagnostic challenge, despite the routine use of various laboratory markers. Recent advancements in the understanding of inflammatory processes have highlighted the role of calprotectin, a heterodimer consisting of S100A8 and S100A9 proteins, with many studies suggesting its clinical value as a biomarker of inflammation. This research aimed to evaluate the usefulness of serum calprotectin (sCal) as a biomarker of urinary tract infection (UTI), which was due to its high pooled prevalence and feasibility of urine culture as a diagnostic reference standard selected for a model of bacterial infection in children. Methods: Febrile children aged 0-36 months with suspected UTI based on positive urinalysis or viral respiratory tract infection were included. Children with significant bacteriuria in urine culture were labeled as cases (n = 58), while those with confirmed viral infection (n = 51), as well as those with suspected UTI but sterile urine culture who went on to develop symptoms consistent with viral respiratory infection (n = 7), were labeled as controls. sCal levels were determined by a commercial immunoassay. Conventional inflammation markers (C-reactive protein, procalcitonin, white blood cell count, absolute neutrophil count, and neutrophil percentage) were measured on the day of the clinical examination. Differences in measured inflammatory markers between cases and controls were analyzed with Mann-Whitney U-test. ROC analysis reported cut-off values with the best sensitivity and specificity to distinguish bacterial UTI from viral respiratory infection. Results: All analyzed inflammatory biomarkers, including sCal, were significantly higher in cases than in controls. Median concentration of sCal was 4.97 µg/mL (IQR 3.43-6.42) and 2.45 µg/mL (IQR 1.63-3.85) for cases and controls, respectively (p < 0.001). For identifying bacterial UTI, sensitivity and specificity of sCal were 77.6 and 69.0%, respectively, at an adjusted cut-off point of >3.24 µg/mL (AUC 80.2%). Conclusion: sCal could have substantial added value in the management of a child with fever and positive urinalysis and is a promising biomarker in distinction between bacterial UTI and viral respiratory causes of febrile illness in children under the age of 3 years.

5.
Clin Chem Lab Med ; 60(5): 714-725, 2022 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-35212494

RESUMO

OBJECTIVES: Hemolysis is associated with erroneous or delayed results. Objectives of the study were to compare four different methods for obtaining hemolysis in vitro on three different analyzers. METHODS: Hemolysis was prepared with addition of pure hemoglobin into serum pool, osmotic shock, aspiration through blood collection needle, freezing/thawing of whole blood. Biochemistry parameters were measured in duplicate at Architect c8000 (Abbott, Abbott Park, USA), Beckman Coulter AU680 (Beckman Coulter, Brea, USA) and Cobas 6000 c501 (Roche, Mannheim, Germany), according to manufacturers' declarations. Cut-off value was defined as the highest value of H index with corresponding bias lower than acceptance criteria. RESULTS: We were not able to obtain results with freezing protocol. On all three platforms, lowest number of analytes were sensitive to hemolysis at H=0.5 using method of adding free hemoglobin. When osmotic shock was used, cut-off values for the most analytes were generally met at lower values. Hemolysis significantly interfered with measurement of potassium and lactate dehydrogenase (LD) at H=0.5 on all platforms. The most of the tested analytes had the lowest acceptable H index when aspiration method was used. At the low level of hemolysis (H=0.8) glucose, sodium, potassium, chloride, phosphate, and LD were affected on all analyzers, with some additional analytes depending on the manufacturer. CONCLUSIONS: Hemolysis interference differs on different analyzers and according to protocol for obtaining hemolysis. Aspiration method was generally the most sensitive to hemolysis interference, while addition of free Hb was the most resistant.


Assuntos
Hemólise , Sódio , Testes Hematológicos , Hemoglobinas/análise , Humanos , Soro/química
6.
Rheumatol Int ; 41(12): 2195-2203, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34623480

RESUMO

The hypothesis of the study was that polymorphisms in promoter regions -238 and -308 of TNF-α could be associated with different clinical outcomes in inflammatory bowel diseases (IBD) and immune-mediated rheumatic diseases (IMRD). The aim was to examine the possible association of both polymorphisms with concentration of C-reactive protein (CRP) and fecal calprotectin (fCAL), onset of the remission and development of the ADA in patients on therapy with anti-TNF inhibitors. The prospective study was done in patients with IBD and IMRD on infliximab (IFX) or adalimumab (ADM). Patients were genotyped for TNF-α -238 and -308 polymorphisms. The concentration of CRP, fCAL, IFX or ADM and antibodies to drugs were measured according to manufacturer's instructions and followed-up for 6 or 12 months. Out of all patients (N = 112), number of patients in remission did not differ according to genotypes (for IBD patients P = 0.509 vs 0.223; for IMRD patients P = 0.541 vs 0.132 for TNF-α -238 and -308, respectively). Initial CRP concentration was higher in IBD patients with TNF-α -308 GG than GA/AA genotypes in patients who failed to achieve remission [11.8 (4.4-39.6) vs 3.1 (1.5-6.5), P = 0.033]. In IBD patients with remission, fCAL concentration after at least 6 months of therapy was higher in TNF-α-308 GG than in GA genotype [52 (25-552) vs 20 (20-20) µg/g, P = 0.041]. Our results showed the association of TNF-α -308 GG genotype with a higher concentration of CRP and fecal calprotectin in patients with inflammatory bowel diseases on IFX or ADM therapy. Clinical remission and development of antibodies to anti-TNF drugs were not associated with TNF-α -238 and -308 polymorphisms.


Assuntos
Adalimumab/administração & dosagem , Doenças Inflamatórias Intestinais/tratamento farmacológico , Infliximab/administração & dosagem , Doenças Reumáticas/tratamento farmacológico , Inibidores do Fator de Necrose Tumoral/administração & dosagem , Adulto , Idoso , Biomarcadores/análise , Proteína C-Reativa/análise , Feminino , Humanos , Complexo Antígeno L1 Leucocitário/análise , Masculino , Pessoa de Meia-Idade , Polimorfismo de Nucleotídeo Único , Estudos Prospectivos , Indução de Remissão , Fator de Necrose Tumoral alfa
7.
Front Med (Lausanne) ; 8: 650619, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33763437

RESUMO

Enthesitis related arthritis (ERA) is a specific subtype of juvenile idiopathic arthritis (JIA), often regarded as an undifferentiated form of juvenile spondyloarthritis (jSpA). While gut is increasingly recognized as origin and/or target of inflammation in adult onset spondyloarthritis (SpA), the incidence of gut involvement in ERA patients is largely unknown. The aim of this study was to measure the concentration of fecal calprotectin (fCAL), a surrogate marker of gut inflammation, in patients with different subtypes of JIA, as well as to correlate the results with various demographic, clinical, laboratory, imaging, and treatment characteristics. The cross-sectional exploratory study involving 71 patients with ERA, other forms of JIA and children complaining musculoskeletal symptoms was therefore conducted. Along with fCAL assessment, a detailed clinical and laboratory examination was performed, including the calculation of a composite disease activity scores. Moreover, MRI of the sacroiliac joints was performed in all ERA and other patients complaining of low back pain. The median concentration of fCAL was highest in ERA patients (33.2 mg/kg, p = 0.02), with a significant difference between those with inactive and active disease (20.0 vs. 57.4, p = 0.01), as well as those with and without MRI signs of sacroiliitis (22.6 vs. 54.3, p = 0.04). The fCAL did not differ depending on the NSAID use (23 vs. 20, p = 0.18), although weak correlation was observed with the treatment duration (r = 0.25, p = 0.03). In conclusion, our findings indicate that a parallel inflammation in musculoskeletal system and gut can occur not just in adults with SpA, but in children with ERA as well.

8.
Biochem Med (Zagreb) ; 31(1): 010708, 2021 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-33594297

RESUMO

INTRODUCTION: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serological tests have been suggested as an additional diagnostic tool in highly suspected cases with a negative molecular test and determination of seroprevalence in population. We compared the diagnostic performance of eight commercial serological assays for IgA, IgM, and IgG antibodies to the SARS-CoV-2 virus. MATERIALS AND METHODS: The comparison study was performed on a total of 76 serum samples: 30 SARS-CoV-2 polymerase chain reaction (PCR)-negative and 46 SARS-CoV-2 PCR-positive patients with asymptomatic to severe disease and symptoms duration from 3-30 days. The study included: three rapid lateral flow immunochromatographic assays (LFIC), two enzyme-linked immunosorbent assays (ELISA), and three chemiluminescence immunoassays (CLIA). RESULTS: Agreement between IgM assays were minimal to moderate (kappa 0.26 to 0.63) and for IgG moderate to excellent (kappa 0.72 to 0.92). Sensitivities improved with > 10 days of symptoms and were: 30% to 89% for IgM; 89% to 100% for IgG; 96% for IgA; 100% for IgA/IgM combination; 96% for total antibodies. Overall specificities were: 90% to 100% for IgM; 85% to 100% for IgG; 90% for IgA; 70% for IgA/IgM combination; 100% for total antibodies. Diagnostic accuracy for IgG ELISA and CIA assays were excellent (AUC ≥ 0.90), without significant difference. IgA showed significantly better diagnostic accuracy than IgM (P < 0.001). CONCLUSION: There is high variability between IgM assays independently of the assay format, while IgG assays showed moderate to perfect agreement. The appropriate time for testing is crucial for the proper immunity investigation.


Assuntos
Teste para COVID-19/métodos , Teste para COVID-19/normas , COVID-19/diagnóstico , COVID-19/virologia , Humanos , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Testes Sorológicos/métodos
9.
Biochem Med (Zagreb) ; 30(2): 020501, 2020 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-32550812

RESUMO

Within the last several years, frequency of vitamin D testing has multiplied substantially all over the world, since it has been shown to have an important role in many diseases and conditions. Even though liquid chromatography - tandem mass spectrometry (LC-MS/MS) has been identified as "gold standard" method for vitamin D measurement, most laboratories still use immunochemistry methods. Besides analytical problems (hydrophobicity, low circulating concentrations, ability to bind to lipids, albumins and vitamin D binding protein, presence of multiple vitamin D metabolites and variable ratios of 25(OH)D2 and 25(OH)D3 in the blood), vitamin D shows great preanalytical variability, since its concentration is drastically influenced by seasonal changes, exposure to sun, type of clothes or sun block creams. Vitamin D is mostly measured in serum or plasma, but new studies are showing importance of measuring vitamin D in pleural effusions, breast milk, urine, synovial fluid and saliva. Besides the main role in calcium homeostasis and bone metabolism, many studies linked vitamin D deficiency with cancer, cardiovascular diseases, diabetes, fertility and many other conditions. However, even though initial observational studies indicated that supplementation with vitamin D might be beneficial in disease development and progression; first results of well-designed randomized controlled prospective studies did not find differences in frequency of cardiovascular events or invasive cancer between patients taking vitamin D supplementation compared to placebo. In the light of these recent findings, validity of excessive vitamin D testing remains an open question.


Assuntos
Deficiência de Vitamina D/sangue , Deficiência de Vitamina D/fisiopatologia , Vitamina D/sangue , Vitamina D/fisiologia , Animais , Doenças Cardiovasculares/sangue , Cromatografia Líquida , Diabetes Mellitus/sangue , Feminino , Fertilidade , Hemólise , Humanos , Hiperlipidemias/sangue , Icterícia/sangue , Pneumopatias/sangue , Masculino , Neoplasias/sangue , Doenças Reumáticas/sangue , Estações do Ano , Espectrometria de Massas em Tandem
10.
Rheumatol Int ; 40(9): 1455-1461, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32462255

RESUMO

Vitamin D is beneficial in patients with immune-mediated rheumatic diseases as it has been shown that it lowers the incidence risk and the level of inflammation. To examine the association between clinical outcomes and initial 25-hydroxyvitamin D [25(OH)D] concentrations in patients with the immune-mediated rheumatic diseases treated with infliximab for 9 months. This study was performed in patients with rheumatoid arthritis (RA), ankylosing spondylitis (AS) and psoriatic arthritis (PsA) treated with infliximab for at least 38 weeks. Disease activity was assessed using Disease Activity Score (DAS28) for RA and PsA and Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) for AS, while the global assessment was performed using the Visual Analogue Scale (VAS). Patients were divided into 2 groups according to 25(OH)D concentration which was classified as deficient or non-deficient (below and above 50 nmol/L, respectively). Concentrations of infliximab (IFX) and C-reactive protein (CRP) were measured according to the manufacturer's instructions.This study was performed in patients with rheumatoid arthritis (RA), ankylosing spondylitis (AS) and psoriatic arthritis (PsA) treated with infliximab for at least 38 weeks. Disease activity was assessed using Disease Activity Score (DAS28) for RA and PsA and Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) for AS, while the global assessment was performed using the Visual Analogue Scale (VAS). Patients were divided into 2 groups according to 25(OH)D concentration which was classified as deficient or non-deficient (below and above 50 nmol/L, respectively). Concentrations of infliximab (IFX) and C-reactive protein (CRP) were measured according to the manufacturer's instructions. The study included 23 patients (14 with RA, 6 with AS and 3 with PsA), median age 54 years, 15 females. Vitamin D deficient and non-deficient groups had median initial concentrations of 38 and 61 nmol/L, respectively. DAS28 and pain on VAS calculated at the 2nd and 38th week showed a statistically significant decrease only in RA and PsA patients with vitamin D deficiency (P = 0.02 and 0.06, respectively). Lower initial concentration of 25(OH)D in patients treated with infliximab was associated with better improvement of clinical measures (DAS28 and VAS) of disease after 9 months of therapy.


Assuntos
Artrite Psoriásica/tratamento farmacológico , Artrite Reumatoide/complicações , Deficiência de Vitamina D/complicações , Vitamina D/análogos & derivados , Adulto , Idoso , Antirreumáticos/uso terapêutico , Artrite Reumatoide/sangue , Artrite Reumatoide/tratamento farmacológico , Proteína C-Reativa/análise , Estudos de Casos e Controles , Feminino , Humanos , Infliximab/uso terapêutico , Masculino , Pessoa de Meia-Idade , Medição da Dor , Estudos Retrospectivos , Índice de Gravidade de Doença , Espondilite Anquilosante/tratamento farmacológico , Vitamina D/sangue , Deficiência de Vitamina D/sangue
11.
Biochem Med (Zagreb) ; 30(2): 020701, 2020 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-32292279

RESUMO

INTRODUCTION: Our aim was to investigate the stability of clinically relevant analytes in pleural and peritoneal fluids stored in variable time periods and variable storage temperatures prior to analysis. MATERIALS AND METHODS: Baseline total proteins (TP), albumin (ALB), lactate dehydrogenase (LD), cholesterol (CHOL), triglycerides (TRIG), creatinine (CREA), urea, glucose and amylase (AMY) were measured using standard methods in residual samples from 29 pleural and 12 peritoneal fluids referred to our laboratory. Aliquots were stored for 6 hours at room temperature (RT); 3, 7, 14 and 30 days at - 20°C. At the end of each storage period, all analytes were re-measured. Deviations were calculated and compared to stability limits (SL). RESULTS: Pleural fluid TP and CHOL did not differ in the observed storage periods (P = 0.265 and P = 0.170, respectively). Statistically significant differences were found for ALB, LD, TRIG, CREA, urea, glucose and AMY. Peritoneal fluid TP, ALB, TRIG, urea and AMY were not statistically different after storage, contrary to LD, CHOL, CREA and glucose. Deviations for TP, ALB, CHOL, TRIG, CREA, urea and AMY in all storage periods tested for both serous fluids were within the SL. Deviations exceeding SL were observed for LD and glucose when stored for 3 and 7 days at - 20°C, respectively. CONCLUSIONS: TP, ALB, CHOL, TRIG, CREA, urea and AMY are stable in serous samples stored up to 6 hours at RT and/or 30 days at - 20°C. Glucose is stable up to 6 hours at RT and 3 days at - 20°C. The stability of LD in is limited to 6 hours at RT.


Assuntos
Líquido Ascítico/química , Análise Química do Sangue/normas , Química Clínica/normas , Derrame Pleural/sangue , Idoso , Idoso de 80 Anos ou mais , Coleta de Amostras Sanguíneas/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
13.
Clin Chem Lab Med ; 57(12): 1882-1887, 2019 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-31343976

RESUMO

Background Serum samples should be centrifuged for at least 10 min at 1300-2500 × g. Changed centrifugation conditions could compromise sample quality. The objective of this study was to compare the serum quality and turnaround time (TAT) using different centrifugation conditions. Methods The study was done in four different periods (A, B, C and D) at different conditions: for 10, 5 and 7 (A, B and C, respectively) at 2876 × g, and 7 (D) min at 4141 × g. Sample quality was assessed as the proportion of samples with: (a) aspiration errors, (b) H index >0.5 g/L and (c) suppressed reports of potassium (K) due to hemolysis. TAT was calculated for emergency samples. The proportions of samples (a), (b) and (c) were compared according to period A. Results The number of aspiration errors was significantly higher in samples centrifuged at 2876 × g for 5 min (p = 0.021) and remained unchanged when centrifuged for 7 min (p = 0.066 and 0.177, for periods C and D, respectively). In periods B, C and D, the proportion of samples with hemolysis was higher than that in period A (p-values 0.039, 0.009 and 0.042, respectively). TAT differed between all periods (p < 0.001), with the lowest TAT observed for B and D. The lowest number of samples exceeding 60-min TAT was observed in period D (p = 0.011). Conclusions The integrity of serum samples is changed with different centrifugation conditions than those recommended. Our study showed that shorter centrifugation at higher force (7 min at 4141 × g) significantly decreases TAT, with unchanged proportion of samples with aspiration errors.


Assuntos
Coleta de Amostras Sanguíneas/métodos , Centrifugação/métodos , Humanos , Reprodutibilidade dos Testes , Soro/química , Fatores de Tempo
14.
Clin Chem Lab Med ; 57(2): 183-194, 2018 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-30055099

RESUMO

Background Nowadays over-the-counter (OTC) drugs and dietary supplements are widely used. Their use can have a significant impact on the validity of laboratory results. The aim of this multicenter European study was to determine the frequency of consumption of various dietary products and OTC drugs among patients and explore their level of knowledge and awareness about the potential impact of various products on laboratory test results. Methods Eighteen European countries participated in this study. The survey was carried out anonymously on a subsequent series of outpatients (n=200) in each participating country. Included were patients who were referred to the laboratory for blood sampling and who voluntarily agreed to participate in the study. The survey included questions about the frequency of consumption of various products, awareness of the importance of informing physicians and laboratory staff about it and information about influence of preanalytical factors in general on laboratory test results. Results In total, 68% of patients were regularly taking at least one OTC drug or dietary supplement. The frequency of patients consuming at least one OTC drug or dietary supplement differed between countries (p=0.001). Vitamins (38%), minerals (34%), cranberry juice (20%), acetylsalicylic acid (ASA) (17%) and omega fatty acids (17%) were the most commonly used in our study. Conclusions The use of various OTC drugs and dietary supplements is highly prevalent in Europe and patients are often not willing to disclose this information to the laboratory staff and ordering physician. The education of both patients and healthcare staff is needed.


Assuntos
Conscientização , Testes de Química Clínica , Suplementos Nutricionais , Conhecimento , Medicamentos sem Prescrição , Pacientes/psicologia , Europa (Continente) , Humanos , Inquéritos e Questionários
15.
Lab Med ; 49(3): 231-238, 2018 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-29528429

RESUMO

OBJECTIVE: To compare the analytical performances of the enzymatic method (EM) and capillary electrophoresis (CE) for hemoglobin A1c (HbA1c) measurement. METHODS: Imprecision, carryover, stability, linearity, method comparison, and interferences were evaluated for HbA1c via EM (Abbott Laboratories, Inc) and CE (Sebia). RESULTS: Both methods have shown overall within-laboratory imprecision of less than 3% for International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) units (<2% National Glycohemoglobin Standardization Program [NGSP] units). Carryover effects were within acceptable criteria. The linearity of both methods has proven to be excellent (R2 = 0.999). Significant proportional and constant difference were found for EM, compared with CE, but were not clinically relevant (<5 mmol/mol; NGSP <0.5%). At the clinically relevant HbA1c concentration, stability observed with both methods was acceptable (bias, <3%). Triglyceride levels of 8.11 mmol per L or greater showed to interfere with EM and fetal hemoglobin (HbF) of 10.6% or greater with CE. CONCLUSION: The enzymatic method proved to be comparable to the CE method in analytical performances; however, certain interferences can influence the measurements of each method.


Assuntos
Eletroforese Capilar/normas , Ensaios Enzimáticos/métodos , Ensaios Enzimáticos/normas , Hemoglobinas Glicadas/análise , Eletroforese Capilar/métodos , Humanos , Modelos Lineares , Reprodutibilidade dos Testes
16.
Biochem Med (Zagreb) ; 28(1): 010707, 2018 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-29472802

RESUMO

INTRODUCTION: Laboratories often modify procedures recommended by the European Urinalysis Guidelines for urine sediment analysis. The aim of this study was to compare the recommended protocol with our routine laboratory procedure and to evaluate the possible impact of modifications in the relative centrifugal force, type of tube, method of supernatant aspiration and urine volume on patient's results. MATERIAL AND METHODS: Firstly, relative centrifugal force was investigated using 20 pairs of samples examined after centrifugation at 400xg and 1358xg. In phase two, 110 samples were examined, paired as: round bottom vs conical tube (N = 46), decanting vs suction of supernatant (N = 100) and 10 mL vs 5 mL of urine sample (N = 101). RESULTS: The number of erythrocytes, leukocytes and squamous epithelial cells was significantly lower after centrifugation at 400xg (P = 0.001, 0.002 and 0.004, respectively). The number of leukocytes was significantly lower in conical tubes (P = 0.010), after the suction of supernatant (P = 0.045) and in 5 mL urine (P < 0.001). The number of squamous epithelial cells was significantly lower after the suction of supernatant (P < 0.001) and in 5 mL urine (P < 0.001). The number of erythrocytes (P < 0.001), total non-hyaline casts (P < 0.001) and the frequency of granular casts (P = 0.039) was significantly lower in 5 mL urine. CONCLUSION: Lower results of leukocytes, erythrocytes, squamous cells and non-hyaline casts were recorded in recommended procedures (centrifugation at 400xg, suction of supernatant, conical tube, 5 mL of sample) than in routine procedure (centrifugation at 1358xg, decanting of supernatant, round bottom tube, 10 mL) used in our laboratory.


Assuntos
Urinálise/métodos , Centrifugação , Técnicas de Laboratório Clínico/normas , Eritrócitos/citologia , Guias como Assunto , Humanos , Leucócitos/citologia , Urinálise/instrumentação
17.
J Clin Lab Anal ; 32(5): e22390, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29479748

RESUMO

BACKGROUND: Study was performed in order: (i) to assess the comparability of glucose, bilirubin, hemoglobin, leukocyte esterase, and protein; (ii) to assess accuracy of glucose, bilirubin, hemoglobin, leukocyte esterase, and protein; and (iii) to evaluate interference of ascorbic acid on the glucose, bilirubin, hemoglobin, and nitrite determination using 2 different dipsticks: iChem Velocity, Iris Diagnostics and Combur-10M, Roche Diagnostics. METHODS: Random urine specimens were included in the study. Comparability, accuracy, and ascorbic acid interference testing were performed. RESULTS: Obtained results have shown almost perfect agreement for all parameters between 2 dipsticks in samples with negative ascorbic acid. Agreement in samples with positive ascorbic acid was not acceptable for bilirubin, protein, nitrite, and hemoglobin. Accuracy was not acceptable for hemoglobin and leukocyte esterase on both dipsticks. Ascorbic acid interference examination has shown that intensity of interference differs between dipsticks. Ascorbic acid interferes with glucose, hemoglobin, nitrite, and bilirubin at different concentrations causing false-negative results. CONCLUSION: Obtained results indicate that it is necessary to determine diagnostic accuracy of used dipstick in order to define purpose of urinalysis. It is very important to choose dipstick with ascorbic acid indicator and to examine ascorbic acid impact on dipstick analytes independently of manufacturer claims.


Assuntos
Ácido Ascórbico/urina , Urina/química , Bilirrubina/urina , Reações Falso-Negativas , Feminino , Glicosúria/metabolismo , Hemoglobinas/metabolismo , Humanos , Masculino , Urinálise
18.
Lab Med ; 49(3): 284-291, 2018 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-29432621

RESUMO

OBJECTIVE: Autovalidation algorithm should be properly designed with clearly defined criteria and any data that do not meet the criteria, must be reviewed and manually validated. The aim was to define the rules for autovalidation in our laboratory information system (LIS), and validate the algorithm prior to its implementation in routine laboratory work. METHODS: Autovalidation was implemented for all routine serum biochemistry tests. The algorithm included analytical measurement ranges (AMR), delta check, critical values, serum indices and all preanalytical and analytical flags from the analyzer. RESULTS: In the validation process 9805 samples were included, and 78.3% (7677) of all samples were autovalidated. The highest percentage of non-validated samples (54.9%) refers to those with at least one result outside the method linearity ranges (AMR criteria) while critical values were observed to be the least frequent criterion for stopping autovalidation (1.8%). Also, 38 samples were manually validated as they failed to meet the autovalidation criteria. CONCLUSION: Implementation of algorithm for autovalidation in our institution resulted in the redesign of the existing LIS. This model of the autovalidation algorithm significantly decreased the number of manually validated test results and can be used as a model for introducing autovalidation in other laboratory settings.


Assuntos
Algoritmos , Testes de Química Clínica/normas , Sistemas de Informação em Laboratório Clínico/normas , Croácia , Humanos , Reprodutibilidade dos Testes
19.
Clin Chem Lab Med ; 56(5): 776-788, 2018 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-29315074

RESUMO

BACKGROUND: The aim of our study was to perform verification of serum indices on three clinical chemistry platforms. METHODS: This study was done on three analyzers: Abbott Architect c8000, Beckman Coulter AU5800 (BC) and Roche Cobas 6000 c501. The following analytical specifications were verified: precision (two patient samples), accuracy (sample with the highest concentration of interferent was serially diluted and measured values compared to theoretical values), comparability (120 patients samples) and cross reactivity (samples with increasing concentrations of interferent were divided in two aliquots and remaining interferents were added in each aliquot. Measurements were done before and after adding interferents). RESULTS: Best results for precision were obtained for the H index (0.72%-2.08%). Accuracy for the H index was acceptable for Cobas and BC, while on Architect, deviations in the high concentration range were observed (y=0.02 [0.01-0.07]+1.07 [1.06-1.08]x). All three analyzers showed acceptable results in evaluating accuracy of L index and unacceptable results for I index. The H index was comparable between BC and both, Architect (Cohen's κ [95% CI]=0.795 [0.692-0.898]) and Roche (Cohen's κ [95% CI]=0.825 [0.729-0.922]), while Roche and Architect were not comparable. The I index was not comparable between all analyzer combinations, while the L index was only comparable between Abbott and BC. Cross reactivity analysis mostly showed that serum indices measurement is affected when a combination of interferences is present. CONCLUSIONS: There is heterogeneity between analyzers in the hemolysis, icteria, lipemia (HIL) quality performance. Verification of serum indices in routine work is necessary to establish analytical specifications.


Assuntos
Bilirrubina/sangue , Análise Química do Sangue , Hiperlipidemias/sangue , Lipídeos/sangue , Hemólise , Humanos , Qualidade da Assistência à Saúde
20.
Clin Chem Lab Med ; 56(4): 574-581, 2018 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-29095694

RESUMO

BACKGROUND: Manual handling of hemolyzed samples is not standardized and is vulnerable to errors. This study aimed to evaluate laboratory errors due to manual handling of hemolyzed samples and to assess the risk they might have for patient safety. METHODS: Data were retrospectively obtained from a laboratory information system for 25 emergency tests from hemolyzed samples. Hemolysis (concentration of free hemoglobin >0.5 g/L) was visually assessed by comparison with a color chart. The reference person reestimated the routinely assessed degree of hemolysis to all samples (n=3185) received in the laboratory in a 1-week period. For each test, the correct and incorrect way of handling results was determined. Risk assessment was performed according to ISO 14971 standard with five categories of risk (S1-S5) and error occurrence (O1-O5). RESULTS: In the studied period, the emergency laboratory received 495 hemolyzed samples (15.5%) with a total of 2518 laboratory test requests (15.5%): 102 (20.6%) of the reports from hemolyzed samples had a comment on hemolysis; 31% of the test results were handled incorrectly (20.7% due to the incorrect release of the test result despite hemolysis interference and 10.3% due to unnecessary suppression), accounting for 4.8% of the total test volume. Tests with the highest combination of risk and occurrence rate were troponin T, potassium and total bilirubin. CONCLUSIONS: Manual handling of hemolyzed samples may lead to risk of errors in reporting results for troponin T, potassium and total bilirubin, which may have an effect on clinical decision. In addition, unnecessary suppression of the sample results unaffected by hemolysis could affect patient outcome.


Assuntos
Coleta de Amostras Sanguíneas , Sistemas de Informação em Laboratório Clínico , Hemólise , Segurança do Paciente , Humanos , Estudos Retrospectivos , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...